M215 Installation and Operation
Copyright © 2012 Enphase Energy 141-00021 Rev 01
4
Important Safety Information
Read this First
This manual contains important instructions for use during installation and maintenance of the Enphase M215™
Microinverter.
To reduce the risk of electrical shock, and to ensure the safe installation and operation of the Enphase
Microinverter, the following safety symbols appear throughout this document to indicate dangerous conditions
and important safety instructions.
WARNING! This indicates a situation where failure to follow instructions may be a safety hazard
or cause equipment malfunction. Use extreme caution and follow instructions carefully.
NOTE: This indicates information particularly important for optimal system operation. Follow
instructions closely.
Safety Instructions
Do not use Enphase equipment in a manner not specified by the manufacturer. Doing so may
cause death or injury to persons, or damage to equipment.
Perform all electrical installations in accordance with all applicable local electrical standards.
Be aware that only qualified personnel should install or replace Enphase Microinverters.
Do not attempt to repair the Enphase Microinverter; it contains no user-serviceable parts. If it fails,
please contact Enphase customer service to obtain an RMA (return merchandise authorisation)
number and start the replacement process. Tampering with or opening the Enphase Microinverter
will void the warranty.
Before installing or using the Enphase Microinverter, please read all instructions and cautionary
markings in the technical description and on the Enphase Microinverter System and the PV
equipment.
Obtain proper approval for the installation from the authorities having jurisdiction.
Be aware that the body of the Enphase Microinverter is the heat sink. Under normal operating
conditions, the temperature is 15°C above ambient, but under extreme conditions the microinverter
can reach a temperature of 80°C. To reduce risk of burns, use caution when working with
microinverters.
Do NOT disconnect the PV module from the Enphase Microinverter without first removing AC
power.
Be aware that the M215 has field adjustable voltage and frequency trip points that you must set
before the system can produce power. Only an authorised installer with the permission and
following requirements of the local electrical authorities should make adjustments.