Enphase M215 Service Manual Page 10

  • Download
  • Add to my manuals
  • Print
  • Page
    / 42
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 9
M215 Installation and Operation
2014 Enphase Energy Inc. All rights reserved. 141-00012 Rev 06
10
Planning for Microinverter Installation
The M215 is compatible with most 60-cell PV modules (to 270W or higher) and installs quickly and easily.
It works with either three-phase 208 VAC or single-phase 240 VAC services. The M215 ships with
integrated DC and AC cables and connectors. The DC connectors attach to the PV module, while the AC
connector attaches directly to the Engage Cable. No additional cabling is needed.
The Engage Cable is available in two connector spacing options and two voltage types to meet varying
site requirements. For Engage Cable ordering information, see “Engage Cable Planning and Ordering” on
page 32.
WARNING: For Be aware that installation of this equipment includes risk of electric
shock. Normally grounded conductors may be ungrounded and energized when a ground
fault is indicated.
Compatibility and Capacity
The M215 can be paired with most 60-cell PV modules. The M215 can also be paired with a 72-cell
module if the voltage and current from the module stays within allowable ranges for the microinverter to
perform safely, notably in warm climates. For more information, see Technical Data on page 35 of this
manual. Refer also to the Enphase Compatibility Calculator at:
http://enphase.com/module-compatibility-calculator-m250-update/ to ensure PV module electrical
compatibility. To ensure mechanical compatibility, be sure to order the correct connector type for both
microinverter and PV module from your distributor.
WARNING: With the M215-60-2LL-S22-IG, S23-IG, or S24-IG, the PV module DC
conductors must be labeled "PV Wire" or "PV Cable” to be compliant with NEC 690.35(D)
for Ungrounded PV Power Systems.
Mechanical Compatibility
Model Number
PV Module Connector Type
M215-60-2LL-S22-IG
1
MC-4 locking connector
M215-60-2LL-S23-IG
1
Tyco locking connector
M215-60-2LL-S24-IG
1
SMK locking connector
M215-60-2LL-S22
2
M215-60-2LL-S22-NA
2
MC-4 locking connector
M215-60-2LL-S23
2
M215-60-2LL-S23-NA
2
Tyco locking connector
M215-60-2LL-S24
2
M215-60-2LL-S24-NA
2
SMK locking connector
1
Microinverter does not require a GEC. Paired modules must use PV (photovoltaic) Wire.